Technical Bulletin
May, 2020 Revision 4
Comparison of FFP2, KN95, and N95 and Other Filtering Facepiece Respirator Classes
                        
Description
Filtering facepiece respirators (FFR), which are sometimes called disposable respirators, are subject to various regulatory standards around the world. These standards specify certain required physical properties and performance characteristics in order for respirators to claim compliance with the particular standard. During pandemic or emergency situations, health authorities often reference these standards when making respirator recommendations, stating, for example, that certain populations should use an “N95, FFP2, or similar” respirator.
This document is only intended to help clarify some key similarities between such references, specifically to the following FFR performance standards:
• N95 (United States NIOSH-42CFR84)
• FFP2 (Europe EN 149-2001)
• KN95 (China GB2626-2006)
• P2 (Australia/New Zealand AS/NZA 1716:2012)
• Korea 1st class (Korea KMOEL – 2017-64)
• DS2 (Japan JMHLW-Notification 214, 2018)
As shown in the following summary table, respirators certified as meeting these standards can be expected to function very similarly to one another, based on the performance requirements stated in the standards and confirmed during conformity testing.
One notable comparison point is the flow rates specified by these standards for the inhalation and exhalation resistance tests. Inhalation resistance testing flow rates range from 40 to 160L/min. Exhalation resistance testing flow rates range from 30 to 95 L/min. Some countries require testing to be performed at multiple flow rates, others at only the high or low end of those ranges. Although this appears to suggest that the standards’ requirements for breathing resistance (also called “pressure drop”) differ from each other, it’s important to understand that pressure drop across any filter will naturally be higher at higher flow rates and lower at lower flow rates. Given typical pressure curves for respirator filters, the standards’ various pressure drop requirements are actually quite similar. This chart shows a representative filter pressure drop curve. If one filter is tested at a high flow rate, the pressure drop performance will be relatively high. If that same filter is tested at a low flow rate, the pressure drop performance will be relatively low.

3M Personal Safety Division
Based on this comparison, it is reasonable to consider China KN95, AS/NZ P2, Korea 1st Class, and Japan DS2 FFRs as “similar” to US NIOSH N95 and European FFP2 respirators, for filtering non-oil-based particles such as those resulting from wildfires, PM 2.5 air pollution, volcanic eruptions, or bioaerosols (e.g. viruses). However, prior to selecting a respirator, users should consult their local respiratory protection regulations and requirements or check with their local public health authorities for selection guidance.
Certification/ Class (Standard)
N95 (NIOSH-42C FR84)
FFP2 (EN 149-2001)
KN95 (GB2626-20 06)
P2 (AS/NZ 1716:2012)
Korea 1st Class (KMOEL – 2017-64)
DS2 (Japan JMHLW-
Notification 214, 2018)
Filter performance – (must be ≥ X% efficient)
≥ 95%
≥ 94%
≥ 95%
≥ 94%
≥ 94%
≥ 95%
Test agent
NaCl
NaCl and paraffin oil
NaCl
NaCl
NaCl and paraffin oil
NaCl
Flow rate
85 L/min
95 L/min
85 L/min
95 L/min
95 L/min
85 L/min
Total inward leakage (TIL)* – tested on human subjects each performing exercises
N/A
≤ 8% leakage (arithmetic mean)
≤ 8% leakage (arithmetic mean)
≤ 8% leakage (individual and arithmetic mean)
≤ 8% leakage (arithmetic mean)
Inward Leakage measured and included in User Instructions
Inhalation resistance – max pressure drop
≤ 343 Pa
≤ 70 Pa (at 30 L/min)
≤ 240 Pa (at 95 L/min)
≤ 500 Pa (clogging)
≤ 350 Pa
≤ 70 Pa (at 30 L/min)
≤ 240 Pa (at 95 L/min)
≤ 70 Pa (at 30 L/min)
≤ 240 Pa (at 95 L/min)
≤ 70 Pa (w/valve) ≤ 50 Pa (no valve)
Flow rate
85 L/min
Varied – see above
85 L/min
Varied – see above
Varied – see above
40 L/min
Exhalation resistance – max pressure drop
≤ 245 Pa
≤ 300 Pa
≤ 250 Pa
≤ 120 Pa
≤ 300 Pa
≤ 70 Pa (w/valve) ≤ 50 Pa (no valve)
Flow rate
85 L/min
160 L/min
85 L/min
85 L/min
160 L/min
40 L/min
Exhalation valve leakage requirement
Leak rate ≤ 30 mL/min
N/A
Depressurizatio n to 0 Pa ≥ 20 sec
Leak rate ≤ 30 mL/min
visual inspection after 300 L /min for 30 sec
Depressurizatio n to 0 Pa ≥ 15 sec
Force applied
-245 Pa
N/A
-1180 Pa
-250 Pa
N/A
-1,470 Pa
CO2 clearance requirement
N/A
≤1%
≤ 1%
≤1%
≤ 1%
≤ 1%
*Japan JMHLW-Notification 214 requires an Inward Leakage test rather than a TIL test.
2
3M Personal Safety Division
Definitions
Filter performance – the filter is evaluated to measure the reduction in concentrations of specific aerosols in air that passes through the filter.
Test agent – the aerosol that is generated during the filter performance test.
Total inward leakage (TIL) – the amount of a specific aerosol that enters the tested respirator facepiece via both filter
penetration and faceseal leakage, while a wearer performs a series of exercises in a test chamber.
Inward leakage (IL)– the amount of a specific aerosol that enters the tested respirator facepiece, while a wearer performs a normal breathing for 3 minutes in a test chamber. The test aerosol size (count median diameter) is about 0.5 micro meter.
Pressure drop – the resistance air is subjected to as it moves through a medium, such as a respirator filter. IMPORTANT: Always read and follow respirator user instructions.
Personal Safety Division
3M Center, Building 235-2W-70 St. Paul, MN 55144-1000
3M PSD products are occupational use only.
In United States of America
© 3M 2020. All rights reserved.
3M is a trademark of 3M Company and its affiliates. Used under license in Canada. All other trademarks are property of their respective owners.